Cislak #400 Root Forceps

SKU: CIS-Z2170
Buying Group Codes:
AVP: Not Coded
CDMV: Not Coded
VP: Not Coded
WDDC: Not Coded

Handle Spring: NS
Handle Size: LONG
Price:
Sale price$433.50

Description

A close relative to the popular Cislak #300 extraction forceps, the #400 forceps are thinner beaked and are therefore more appropriate for those smaller teeth or for removing root fragments. Like the #300s, they close parallel to the tooth allowing the user to comfortably grip and twist the tooth after appropriate luxation. The parallel jaws also put less pressure at the base of the crown like some other styles of extraction forceps, thereby reducing the chance of breaking the crown during extraction.

Handle Options:

  • S - With spring
  • NS - Without spring

  • Size Options:
  • LONG - Long Handle
  • SHRT - Short handle

  •  

    Can't Find What You Are Looking For?
    We can customize any Cislak instrument. If the combination of tip(s), handle, or shank is not available online please contact us to place your custom order!

    Cislak Manufacturing is the source for quality crafted dental hand instruments for the veterinarian. All Cislak instruments are made of the highest quality materials in the USA or Europe (the only exceptions are noted). Cislak’s instruments are all hand checked so they meet their exacting standards and have a life time warranty. Cislak has worked with a number of veterinary dental specialists to develop a line of instruments with specific veterinary needs in mind. Knowing the importance of being able to hold the instrument correctly, Cislak offers multiple handle choices to suit all customers.

    Cislak instruments also come with the added benefit of the ability to be re-tipped because they are manufactured in such a way that the handle and shank can be separated. Customers can then save the handles of any damaged or worn instruments and send them to Serona for re-tipping, rather than replacing them with new instruments at a higher cost.

    Cislak’s warranty covers all of their instruments for 100% of all material failure and workmanship defects. Material failure is defined as any defect, pitting or corroding or breakage due to a fault in the steel or handle of an instrument. Any instrument found to have these types of defects will be repaired or replaced.

    Cislak’s warranty does not cover instruments that break due to over or improper use, improper cleaning or sterilization (sterilizing with bad water or the wrong temperature), dropped instruments, improper sharpening or normal wear and tear.

    You may also like

    Recently viewed